Conventional Gas Suppression Detection Panel
A Gas suppression panel is a control unit used in fire suppression systems that employ gases such as carbon dioxide (CO2), Halocarbon agent or Inert Gases to extinguish fires. The panel is responsible for controlling the release of gas from the storage cylinders or tanks and directing it to the protected area.
 
The gas suppression panel is typically located near the protected area and includes a set of sensors that detect fire and initiate the release of gas. In addition to controlling the release of gas, the suppression panel may also include alarms and other safety features that warn occupants of the protected area to evacuate before the gas is released. These safety features help prevent injury or harm to individuals who may be present during a fire event.
 
Overall, the gas suppression panel plays a critical role in ensuring the effective operation of gas-based fire suppression systems, protecting property and lives in the event of a fire.

Kidde 2.0 / XTL Suppression Control Unit

The Kidde Fire Systems AEGIS™-XLT Conventional Control Units are designed to deliver fire suppression in demanding industrial environments. These fully-featured, single-hazard conventional control units are available in three variations – NEMA 1, NEMA 4 and NEMA 12. All enclosures are constructed to protect the interior components from contamination.

 

AEGIS-XLT Control Units support a large range of release-on and pre-discharge time settings. These units are engineered to meet the needs of LP CO2, Water Mist and Spurt applications. They provide a high degree of programming flexibility, a full complement of input and output circuits, and triple redundancy (Triple-R) safeguards to substantially reduce inadvertent activation of the suppression system caused by microprocessor failure.

 

The Kidde Fire Systems full line of suppression and other detection equipment provide efficient, effective fire suppression solutions to help protect life, high value assets and equipment where downtime has a major financial impact.

 

Applications :

  • Coal Handling Systems
  • Areas Containing High-Value Assets
  • Cold Rolling Mills
  • Commercial Applications
  • Dust Collectors
  • Electrical Equipment Rooms
  • Exhaust Ducts
  • Hydroelectric Generators
  • Industrial Facilities
  • Gas/Diesel Generator Units
  • Printing Presses
  • Grinding & Machining Units
  • Process Rooms
  • Lube Oil Rooms/Areas
  • Storage Areas
  • Manufacturing Operations

AEGIS-XLT Control Units Features :

  • NEMA 1, NEMA 4 and NEMA 12 enclosures for Commercial, Outdoor (Weatherproof) and Industrial (Dust Tight and Oil Resistant) Applications.
  • Seven (7) input and five (5) output circuits
  • 5.4 Amp power supply and 68 AH battery charging capacity
  • Triple-R Protection substantially reduces inadvertent activation of the suppression system caused by microprocessor failure
  • Listed for use with Kidde Fire Systems, Fenwal® and Chemetron® agent release devices including Control Heads and Initiators
  • Large range of release-on and pre-discharge time settings
  • Spurt, non-latching Manual Release function allows push button start and stop of agent release
  • Class A wiring supported without any additional hardware
  • Thermal cycling with selectable on/off, wait and repeat sequence times
  • Heater available for operation below 32°F (NEMA 4 and NEMA12 enclosures)
  • Three (3) programmable and one (1) dedicated trouble relay

 

Approvals & Listings:

  • FM to NFPA 72, ANSI/UL 864 - 9th edition
  • UL to ANSI/UL 864 9th edition

 

PFC Series Releasing Control Panel

The Potter Model PFC-4410RC is a flexible multi-hazard releasing control panel that is well suited for a number of applications. The PFC-4410RC is listed for use with pre-action and deluge sprinkler suppression systems and agent based fire suppression systems.

 

The panel utilizes a microprocessor-based system that has 24 Standard Programs, which covers a majority of installations. The simple to follow Menu Structure programs the entire system in a matter of minutes. In addition to the Standard Programs, the panel allows custom programming to accommodate any installation.

 

The PFC-4410RC is housed in a durable steel cabinet with removable door and key lock. The panel is available in either a red or white finish and an optional flush mount trim ring is available. The cabinet contains knockouts on the side, back and top of the cabinet to ease installation. In addition, the cabinet will house up to 18 amp-hour batteries that will provide in excess of 90 hours of standby power.

 

 

PCF Releasing Control Units Features :

  • Multi-Hazard Operation
  • Four Class B Initiating Circuits
  • Two Class B Supervisory Circuits **
  • Four Class B Output Circuits
  • Programmable Cross Zoning
  • Supervised Microprocessor
  • 32 Character Alpha-Numeric LCD Display
  • Custom Banner Message and Zone Description text
  • Custom Zone Description Text
  • On Board Menu Driven Programming Controls
  • Releasing Circuits Protected From False Activation
  • Continuous or Timed Discharge
  • 40 Event History Buffer
  • Walktest with Automatic Time-out
  • Alarm, Trouble Supervisory, and Waterflow relays
  • Optional Class A Initiating Zone and output module
  • 34 character LED supplemental display
  • 24 Standard Programs in Panel Memory
  • Password Protection for all Programming
  • 24 Hour Clock
  • Suitable for agent or water-based extinguishing
  • Programmable pre-discharge timers*
  • One Class B Abort circuit* (Defaults to additional supervisory zone in water based mode.)
  • Four Abort modes*

 

* Available in Chemical mode only

** One zone programmable as abort in chemical mode.

Dimension :

  • 18-1/4" x 14-1/2" x 4-3/4"

Approvals & Listings:

  • UL and ULC Listed
  • FM Approved
  • NYMEA Accepted
  • CSFM Approved
  • CE Marked and RoHS Compliant

 

 

PATENT System 88i Suppression Control Unit

System 88i extinguishing control panels is a variant of the fire alarm range and employs the same proven detection, notification and actuation circuits. Favoured for reliability and ease of use, this range has been the product of choice for data centres, server rooms and telecommunication facilities.

 

Applications :

Can be used with most extinguishing systems – FM200 ® / Novec ® / Inert Gas / CO2 / water mist.

 

System 88i Control Units Features :

  • 1 to 60 dual risk zoning
  • Cross zones activation
  • Countdown timer selectable from 10, 30 , 60 and 90 secs. (120 secs is an option) § Cross-zones actuation as standard
  • “Any 2 zone” actuation is an option
  • Indications for supervision of Remote Manual Release
  • “line-fault” and “activated” conditions § Indications for supervision of Actuator “line-fault” and “fired” conditions § Gas Released positive feedback indication
  • Indications for “Remote Abort” activation
  • Monitoring of actuator head disconnection / cylinder low pressure
  • On-board inhibition of detection zone, remote manual release, actuation and auxiliaries § Resound/silence facilities for 1st alarm and 2nd alarm notifications
  • Auxiliary outputs for 1st and 2nd detection with isolation facilities
  • Field selectable for individual firing with common signal output (Bell, Strobe, Evacuate Signage, Auxiliary 1, Siren, Gas Fired Signage, Auxiliary 2)
  • Options of alphanumeric display module with recordable event, date and time of zone fire, manual release, actuator activated, gas discharged and abort actuation.
  • Compatible with conventional detectors & alarm devices that are certified international standards such as UL or EN
  • EN complied power supply with capacities from 2A to 22A

 

Approvals & Listings:

  • PSB Listed

 

Vanguard V5 Advance Extinguishing Panel

V5 Advance range of Fire Extinguishing Panel ranging from 1 to 136 zones. All panels are tested to comply to BS EN 54-2, BS EN 54-4 and SS CP10.

 

The solid state electronics makes the V5 Advance Panel highly reliable and rugged. Standard cross-zoned detection verification further reduces unwanted release of extinguishant.

 

Fire Extinguishing Panel is usually used to provide protection for rooms containing very high asset value or mission critical equipment. Vanguard understands the types of risk that a V5 Fire Extinguishing Panel is required to protect and has built into the V5 Advance panel a comprehensive range of monitoring circuits to ensure timely detection of any fault developing in the panel. In addition to the standard features, the V5 Fire Extinguishing Panel is provided with a range of upgradeable features.

 

Applications :

Can be used with most extinguishing systems – FM200 ® / Novec ® / Inert Gas / CO2 / water mist.

 

Vanguard V5 Control Units Features :

  • Available up to 136 zones
  • Easy to use.
  • Dedicated isolation buttons
  • Colour Coded and Numbered Buttons
  • Digital Countdown Timer
  • Compatibility
  • Minimum maintenance requirement
  • Diagnostics facilities
  • Solid state electronics
  • Compliance to regulation - CP10, EN54 Part 2 & 4

 

Approvals & Listings:

  • PSB Listed

 

HOCHIKI HCVR-3 Conventional Releasing 3 Zone Control Unit

 

The HCVR-3 is a 3 zone conventional releasing fire alarm control panel that is UL Listed and FM Approved for releasing. The HCVR-3 can be configured to activate releasing by a single zone or combination of any two zones. The LCD display is used to show the countdown timer during activation of the releasing sequence.

 

The HCVR-3 is fully programmable using simple menu options. The panel is a single board construction which provides an easy replacement solution. It is also compatible with a wide

range of devices.

 

HCRV-3 Control Units Features :

  • Three detection zones
  • Three notification appliance circuits
  • Any single zone or combination of zones can be configured to release
  • Fully programmable using simple menu options
  • Simple, single board construction
  • Compatible with a wide range of detection devices
  • Built-in manual release switch with separate manual release input circuit for external switch
  • Releasing countdown timer displayed on built-in LED display
  • Configurable releasing delay up to 60 seconds in 5 second intervals
  • Configurable releasing duration up to 5 minutes in 5 second intervals
  • Built-in relays for Fire, Trouble, Stage 1, Stage 2, Extract, and Local Fire
  • 240v input, 60Hz/50Hz

 

Approvals & Listings:

  • FM approved
  • UL Listed

 

 

Extinguishing Control Panel Accessories Devices

 

Extinguishing control panels typically use different types of fire detection devices to monitor for the presence of a fire and activate the fire suppression system.

 

Here are some common types of devices that can be used with an extinguishing control panel:

 

  • Smoke detectors
  • Heat detectors
  • Flame detectors
  • Manual Release Station
  • Abort station
  • Bell
  • Strobe & Horn
  • Evacuate Light
  • Gas discharge Light

 

 

Extinguisher Control Unit Download:

 

Devices & Accessories Download:

 

Drawing Download:

 

Copyright 2023 - www.eunixfire.com -  All Rights Reserved